Stainless Steel Sanitizing Sink for Cleanrooms: The First Line of Defense in Clean Environments
Core Necessity:
• Establishes the primary barrier for personnel hygiene and disinfection, preventing human-borne contamination
• Meets mandatory GMP/FDA requirements for cleanroom sanitation facilities
• Enables touch-free disinfection to avoid cross-contamination
• Provides stable purified water/disinfectant supply systems
| Common Specification Parameters for Stainless Steel Sanitizing Sinks in Cleanrooms | ||
| Parameter Category | Specification Configuration | Applicable Scenarios |
| Basic Specifications | ||
| Material | 304/316 Stainless Steel, Thickness 1.2-1.5mm | Standard/High Corrosion Environments |
| Surface Treatment | Electropolishing, Ra ≤0.8μm | Complies with GMP Standards |
| Counter Height | 850mm/900mm | Ergonomic Design |
| Structural Dimensions | ||
| Single Station | 600×600×850mm | Small Cleanrooms |
| Double Station | 1200×600×850mm | Moderate Personnel Areas |
| Triple Station | 1800×600×850mm | High-Density Personnel Areas |
| Functional Configuration | ||
| Control Method | Sensor-Activated/Elbow-Operated/Foot-Pedal | Different Cleanliness Grade Requirements |
| Faucet | Cold Water Only/Cold & Hot Mixed | Seasonal Requirement Options |
| Disinfectant Dispenser | 500ml/1000ml Capacity | Manual/Auto-Sensor |
| Technical Parameters | ||
| Water Supply Pressure | 0.05-0.6MPa | Stable Water Flow Requirements |
| Temperature Resistance | -30℃ to 120℃ | High-Temperature Disinfection Tolerance |
| Drain Outlet Diameter | Φ50mm/Φ75mm | Rapid Drainage Design |
| Accessory Configuration | ||
| Soap Dispenser | 500ml Stainless Steel Container | Standard |
| Hand Dryer | High-Speed Air Curtain Type | Optional |
| Shelf | 304 Stainless Steel Material | Optional |
Selection Guide:
1. 304 stainless steel is recommended for standard cleanrooms, while 316 is preferred for highly corrosive environments
2. Full sensor-activated configuration is recommended for Class 100/1000 clean areas
3. Drainage systems require anti-backflow devices
4. Non-standard dimensions can be customized according to actual requirements
Installation Recommendations:
Reserve maintenance space ≥300mm
Stainless steel pipes are recommended for water supply and drainage
Power Supply: AC220V±10%, 50Hz
Installation Environment Temperature: 5-40℃
The above specifications represent common industry standard configurations. Specific projects require adjustments and optimization based on actual usage needs.